V2G Analyzer
CCS Protocol Analyzer
CCS Protocol Analyzer
Gridwiz V2G Analyzer is an equipment that sniffing the packet and analyzes the charging message between Electric Vehicle(EV) and EV charger in CCS standard. It is suitable for testing the prototype of development or for field testing. |
Components
No. | Name | Description |
1 | Gridwiz V2G Analyzer Hub Box | Gridwiz V2G Analyzer Hub Box is consisted of Contorl Pilot Measurement, HomePlug Green PHY modem, and PLC packet sniffer. The collected CP (PWM) data and sniffed PLC packet are delivered to the laptop which running Gridwiz V2G Analyzer |
2 | Gridwiz V2G Analyzer | Gridwiz V2G Analyzer is a software that providing CP (PWM) monitoring and V2G message analysis. The V2G Analyzer visualizes the results of monitoring or analysis about CP (PWM), V2G Message, and DC Charging Sequence as chart and table. |
3 | Laptop and case | Laptop installed V2G Analyzer and laptop case (Laptop adaptor and ethernet cable are included) |
4 | CCS type1/ type 2 Cable | Two couplers (CCS type 1 and CCS type 2) and cable case |
GW V2G Analyzer
Gridwiz V2G Analyzer (S/W) | |
Feature | PWM Monitoring V2G Message Analysis |
Standard | DIN SPEC 70121:2014, IEC 61851-1 |
User Interface | CP monitoring Charging message Charging sequence Save and load traces (V2G message, PWM value) |
Hub Box
CCS type 1 Cable | CCS type 2 Cable | |
Operation Voltage | 1000 V DC | 1000 V DC |
Current Carrying Capacity | 200A | 200A |
Maximum Performance | 200kW | 200kW |
Coding Resistance | 480/150 Ω | 480/150 Ω |
Temperature Range | -30 C° ~ +40 C° | -30 C° ~ +40 C° |
Temperature Resistor | PT 1000 | PT 1000 |
Cable Length | 1.5m | 1.5m |
Cable Case | ||
Dimension | 61cm X 30.5cm X 45cm | |
Weight | 19kg (Including cables) |