SECC TD & EVCC TD
Test Device for EV & EVSE
Gridwiz SECC TD and EVCC TD fully support various international standards such as CCS and ISO 15118, and are optimized for verifying the interoperability of electric vehicle charging systems.
Item | Description |
---|---|
CCS modem | Electric Vehicle Communication Controller / Supply Equipment Communication Controller Signal Level Attenuation Characterization (SLAC) PWM detection and Control Pilot state transition in accordance with IEC61851-1 HomePlug Green PHY (IEEE 1901 BPL) |
PLC Technology | HomePlug Green PHY (IEEE 1901 BPL) |
CCS Standard | DIN SPEC 70121 & ISO 15118 DC EIM |
Interface (Expansion) |
RS-232 (Debug and Firmware Update)
CP, PE (PLC communication interface) |
Dimension | 150 x 197 x 46 (W x L x H, mm) |
Display | Character LCD |
Power | 12 VDC |
EV Simulator for CCS EVSE Development
SECC TD is an EV Simulator embedded with the common charging sequences for the communication between EV Charger and Electric Vehicle (EV) in accordance with DIN SPEC 70121, and ISO 15118.
SECC TD is an economically efficient product, which includes EVCC and BMS Simulator to get the accurate correspondence without Electric Vehicle.
On the LCD display, the user can monitor real-time EV charging sequence without connecting PC program. This device is also best fit for testing communication in the maintenance and product inspection as well as developing of the EV Charger.
The user can check the following data in each charging sequence:
- PWM signaling based on IEC 61851 (CP duty, CP voltage)
- SLAC sequence for PLC association of HomePlug Green PHY standard
- HLC (High Level Communication) of charging protocol for data communications
PLC Signal
PLC Signal | |||||
---|---|---|---|---|---|
Parameter | Conditions | Min | Typ | Max | Unit |
PSD1 of HPGP2 Signals 1) PDS: Power Spectral Density 2) HPGP: HomePlug Green PHY |
Form 1.8 to 30 MHz RBW=9kHz on 50Ω |
- | -75 | -73 | dBm/Hz |
Peak-Peak Voltage of HPGP Signals | Control Pilot signal steady at high or low level | - | - | - | V |
PWM Signal
PWM Signal | |||||
---|---|---|---|---|---|
Parameter | Conditions | Min | Typ | Max | Unit |
Frequency | Tolerance 0.5% | - | 1 | - | kHz |
Duty Cycle | Tolerance 1% | - | 5 | - | % |
Voltage Level | Tolerance ±0.6V | - | ±12 | - | V |